6Nm, AC/DC24V Actuator for Electric valve, ON/OFF type with manual override for water flow control

Category : Home Improvement | Plumbing
USD 77.54

6Nm, AC/DC24V Actuator for Electric valve, ON/OFF type with manual override for water flow control

Description

Product Name

6Nm, AC/DC24V Actuator for Electric valve, ON/OFF type with manual override for water flow control

IMG_20160328_114314IMG_20160328_152937IMG_20160328_152904IMG_20160328_152823IMG_20160328_113918

Application

HVAC system

Heating system

Water treatment system

Industrial equipments

 

Actuator

Working voltage: AC/DC24V±15%

Out put torque force: 6Nm

Angle of rotation: 90 degree.

Protection class: IP54

Operation time: 50S-120S

Manual handle   Automatic overload protection system (Manual selection of ball rotation direction: C.W. /C.C.W, factory setting is C.W)

Flow characteristic: equal percentage

Flow range: 0%-100%

 

Actuator and valve body match

Model No.

Working Voltage

Actuator type

Output torque

Consumption

Valve body

WVA4-104

24VAC/DC±15%

ON/OFF

4N.m

 

DN25,DN20,DN15

WVA4-106

24VAC/DC±15%

ON/OFF

6N.m

 

DN50, DN40,DN32,

WVA4-110

24VAC/DC±15%

ON/OFF

10N.m

 

DN50

 

Installation:

  1. Ensure that the valve body is in the full open status.

  2. Ensure that the actuator is in the fully open position as the follow picture:

  3. Aligning the valve stem, press down the aluminum alloy spindle.

Proportional valve description 002

Change of running direction

The rotation can be reversed by pushing the CCW/CW switch on the casing. (Factory settings: "CW")

Proportional valve description 003

Dimension and Wiring Actuator

4Nm Actuator

Proportional valve description 004 4Nm

6Nm/10Nm Actuator

Proportional valve description 005 6Nm

Connector Dimension

Proportional valve description 006Proportional valve description 007

Wiring diagram

Proportional valve description 008

Black wire is commen wire.

Brown wire is open wire, when power is on, valve will turn counterclock wise, valve open.

Red wire is close wire, when power is on, valve will turn clock wise, valve close.

When power failure, valve will stay at current position. So, the open angle can be fixed according to the time of power supply.

Specification

Brand Name : Tsai Fan

Structure : Ball

Certification : CE

Origin : CN(Origin)

Port Size : DN15 to DN50

Pressure : Low Pressure

Power Source : DC

Standard or Nonstandard : Standard

Actuator Mode : With Manual And Instruction

Media : Water

Is Smart Device : no

Power : electricity

Material : BRASS

Model Number : TFA4-106

Temperature of Media : Normal Temperature

Working voltage : AC/DC24V

Valve type : ON/OFF

Manual override : Yes

Control wires : 3 wires

Torque force : 6Nm

+